空壓機的停用(yòng)在各個單位都常(chang)有發生。那麼在初(chu)次開機前🧑🏽🤝🧑🏻空壓機(ji)停放時間超過三(sān)個月或空壓機⭐停(ting)用時間超過三個(ge)月,再次開機前需(xu)要采取有效🛀措施(shi),bi須先請專業空壓(ya)機人員🛀🏻對機器進(jin)行保養檢測,制定(dìng)安🏒全措施,避免開(kāi)機後發生不良狀(zhuàng)況。
The shutdown of air compressors often occurs in various units. Then, before the first start-up, the air compressor parking time is more than three months or the air compressor parking time is more than three months. Before the second start-up, effective measures need to be taken. The Bi must first ask professional air compressor personnel to carry out maintenance and inspection of the machine, and formulate safety measures to avoid adverse conditions after the start-up.
1、先檢查電路狀(zhuàng)态,是否正常供電(diàn),電壓是否穩定;測(cè)量電動機㊙️絕緣電(dian)阻,數值大于1MΩ。
1. Check the state of the circuit first, whether the power supply is normal, whether the voltage is stable; Measure the insulation resistance of the motor, the value is greater than 1M.
2、檢查(chá)空壓機配件上是(shi)否含有積水,灰塵(chen),及時清理。
2. Check whether there is water and dust on the spare parts of air compressor, and clean them up in time.
3、對進氣(qì)口,出氣口全面檢(jian)測,防止發生堵塞(sai)現象
3. Overall inspection of intake and outlet to prevent blockage
4、在上述都已(yǐ)經完成的情況可(ke)以接通電源,查看(kan)電腦控制⁉️器是否(fou)正常運行
4. If all the above have been completed, the power supply can be connected to check whether the computer controller is working properly.
5、更換三(sān)濾和潤滑油。因為(wéi)在長期不用的情(qing)況下,三濾,油❓可㊙️能(néng)✂️發生老化現象,從(cong)而造成空壓機開(kāi)機運行時❌間不長(zhang)即結膠積碳或堵(du)塞,油路不暢使空(kōng)壓機主機或其他(tā)零部件損壞。
5. Replace three filters and lubricants. Because in the case of long-term non-use, three filters may cause oil aging phenomenon, which causes the air compressor start-up time is not long, that is, cementing carbon deposit or blockage, oil circuit is not smooth, so that air compressor main engine or other parts are damaged.
6、專業(yè)人員試機,電路改(gǎi)造後人工控制加(jia)載卸載,先空載運(yùn)行10分🍓鐘以上,檢測(cè)各項指标和震動(dòng)、噪音等正常,再進(jin)行加載,查看各部(bù)件運行正常即可(kě)。
6. Professional personnel test machine, after circuit modification, manual control loading and unloading, first no-load operation for more than 10 minutes, detection of various indicators and vibration, noise and other normal, then load, check the normal operation of the components.